A Quantitative Flurometric Assay for the Measurement of Antibody to Pasteurella haemolytica in Cattle

AUTOR(ES)
RESUMO

A rapid, simple fluorometric method is described for measuring antibody to Pasteurella haemolytica in sera of cattle. Various antigen preparations were compared for the test including live, formalin-killed and phenol-killed P. haemolytica. A preparation composed of formalin-killed organisms from a 22 hour culture gave consistent results and was used in the studies. The test was reproduciable with percent coefficients of variation for fluorescent signal unit values on ten or more replicate samples ranging from 5.7 to 28.0. Sera from calves vaccinated by aerosol exposure to live P. haemolytica had up to a five-fold increase in antibody titer as measured by the flurometric method test during a 21 day period. Fluorometric method titers were comparable to those obtained by the indirect bacterial agglutination test. There was no seroconversion to P. haemolytica in calves vaccinated by aerosol exposure of P. multocida. The major advantages of the fluorometric method test over conventional methods are that the assay does not require serial dilutions of serum samples and thus limits time and effort to determine antibody titers.