Aspectos analíticos em TS-FF-AAS : estudo de interferências e aplicação para a determinação de metais em vinhos e sucos / Analytical aspects of ts-ff-aas: study of interferences and application for determinations of metals in wines and grape juices
AUTOR(ES)
Daniela Schiavo
DATA DE PUBLICAÇÃO
2007
RESUMO
In this work, it was evaluated the effects of interferences caused by major and minor constituents on Co, Cu and Mn atomized by flame atomic absorption spectrometry (FAAS) and by thermospray flame furnace atomic absorption spectrometry (TS-FFAAS). The main concomitants were chosen according to the typical concentrations found in foods and beverages. The liquid samples were propelled by a peristaltic pump through a ceramic capillary conductively heated by a flame and then into a nickel tube. The nickel tube was positioned on a lab-made stainless steel support with four ceramic pins on the flame burner. The thermospray was generated inside the heated ceramic capillary in contact with the nickel tube. The samples were introduced into the flame heated tube without the need of a nebulizer. Additionally, the sensitivity was significantly improved by increasing the residence time of the free analyte atoms in the observation zone. Severe interference effects were observed for all analytes. These interference processes require the application of either previous separation steps or special strategies of calibration. Afterwards, the applicability of TS-FF-AAS was evaluated for direct determination of Cu, Cd and Pb in wines and grape juices. The developed procedure did not require any step of digestion. The effect of ethanol was evaluated and samples were properly diluted before measurements. All determinations were carried out adopting optimized conditions and quantification was based on the standard additions method. Limits of detection (LOD) of 12.9, 1.7 and 5.32 g L-1 (n = 14) for Cu, Cd and Pb, respectively, were obtained using optimized conditions for wine samples. Relative standard deviations (RSD, %) of 2.7, 2.1 and 2.6% for Cu, Cd and Pb were obtained (n = 6). Limits of detection (LOD) for grape juice samples were 13.7, 0.90 and 5.55 g L-1 and relative standard deviations (RSD, %) of 3.3, 2.0 and 2.3 for Cu, Cd and Pb, respectively. The analytical throughput was 45 determinations h-1 and accuracy was proved by addition-recovery experiments.
ASSUNTO(S)
vinho interferência ts-ff-aas quimica espectroscopia de absorção atômica suco forno sobre chama
ACESSO AO ARTIGO
http://www.bdtd.ufscar.br/htdocs/tedeSimplificado//tde_busca/arquivo.php?codArquivo=2063Documentos Relacionados
- Sistema TS-FF-AAS com chama acetileno-ar como alternativa em relação à chama acetileno-óxido nitroso em FAAS na determinação de estanho
- Performance of Avocado Seed Activated Carbon as Adsorbent for Highly Sensitive Determination of Cd Using a Flow Injection System Online Coupled to TS-FF-AAS
- Avaliação de aspectos configuracionais e analiticos da tecnica TSFFAAS
- Avaliação da viabilidade da determinação de cobalto e cromo em alimentos por espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS-FF-AAS).
- Analytical determination of sulphites in wines and fruit juices and estimation of their intake.