Ciprofloxacin pharmacokinetics in burn patients.

AUTOR(ES)
RESUMO

Many drugs exhibit altered pharmacokinetic parameters in burn patients. We prospectively evaluated the pharmacokinetics of ciprofloxacin in eight burn patients with active infections. Each patient received a 400-mg dose of ciprofloxacin intravenously (i.v.) every 8 h, with each dose infused over 1 h by using a rate control device. Blood samples for analysis of plasma ciprofloxacin concentrations, determined by high-performance liquid chromatography, were obtained immediately predose, at the end of the infusion, and 1, 2, 3, 4, 5, 6, and 7 h after the end of the infusion. Urine was collected from 0 to 2, 2 to 4, and 4 to 8 h following the same dose, and an aliquot was saved for determination of the ciprofloxacin concentration. Urine was also collected for 24 h prior to this dose for measurement of creatinine clearance (CLCR). Pharmacokinetic parameters were estimated by noncompartmental analysis. Mean maximum and minimum plasma ciprofloxacin concentrations were 4.2 +/- 1.1 and 0.70 +/- 0.55 microgram/ml, respectively. Mean values for clearance (CL), renal clearance (CLR), volume of distribution, terminal elimination rate constant, half-life (t1/2), and area under the concentration-time curve (AUC) were 29.1 +/- 17.5 liters/h, 13.5 +/- 10.1 liters/h, 1.75 +/- 0.41 liters/kg, 0.222 +/- 0.098 h-1, 4.5 +/- 3.9 h, and 20.7 +/- 16.6 micrograms.h/ml, respectively. CL was higher and t1/2 was shorter than noted in previous studies of acutely ill, hospitalized patients. A good correlation was noted between creatinine clearance CL(CR) and both total ciprofloxacin CL (r = 0.85) and CLR (r = 0.84). A moderate inverse correlation was noted between percent body surface area burned and total ciprofloxacin CL (r = -0.55). An AUC/MIC ratio above 125 SIT-1 (where SIT is serum inhibitory titer), which has been strongly correlated with clinical response and time to bacterial eradication, was achieved in five of eight patients (63%) with a MIC of 0.25 microgram/ml. At a ciprofloxacin dosage of 400 mg i.v. every 12 h, an AUC/MIC ratio above 125 SIT-1 would have been achieved in only two of eight patients (25%). We conclude that ciprofloxacin CL is highly variable, but generally increased, in burn patients compared with that in acutely ill, general medical and surgical patients. Because of an increase in CL, a ciprofloxacin dosage of 400 mg i.v. every 8 h is more likely to produce the desired response in burn patients than the same dose given every 12 h.

Documentos Relacionados