Comparative evaluation of the E test, agar dilution, and broth microdilution for testing susceptibilities of Helicobacter pylori strains to 20 antimicrobial agents.
AUTOR(ES)
Piccolomini, R
RESUMO
The Epsilometer test (E test; AB Biodisk, Solna, Sweden), a new quantitative technique for the determination of antimicrobial susceptibility, was compared to reference methods (agar dilution and broth microdilution) for the antimicrobial susceptibility testing of Helicobacter pylori. Seventy-one H. pylori strains isolated from patients with duodenal ulcers were tested against 20 antimicrobial agents. The E test and the agar dilution method were carried out on Mueller-Hinton agar; the broth microdilution method was performed with Mueller-Hinton broth. The E-test results showed excellent correlation with the agar dilution results, with 91.3 and 98.8% agreement within 1 and 2 log2 dilution steps, respectively, in a total of 1,350 tests. The correlation between the E-test results and the broth microdilution results was slightly higher, with 91.6 and 99.1% agreement within 1 and 2 log2 dilution steps, respectively, in a total of 1,317 tests. There were six major errors and two very major errors by the metronidazole E test compared to the results obtained by reference methods. Excellent agreement between E-test, agar dilution, and broth microdilution results was found for resistance to erythromycin (8%), clarithromycin (6%), and tetracycline (6%). Our results confirm that the E test is comparable to standardized methods for susceptibility testing. Therefore, the E test is a reliable and alternative method for testing H. pylori susceptibility to a wide range of antimicrobial agents in clinical practice.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=229853Documentos Relacionados
- Comparison of agar dilution, broth microdilution, E-test, disk diffusion, and automated Vitek methods for testing susceptibilities of Enterococcus spp. to vancomycin.
- Antimicrobial susceptibility testing for Helicobacter pylori isolates from Brazilian children and adolescents: comparing agar dilution, E-test, and disk diffusion
- Antipneumococcal Activity of Telithromycin by Agar Dilution, Microdilution, E Test, and Disk Diffusion Methodologies
- Comparison of agar dilution, broth microdilution, disk diffusion, E-test, and BACTEC radiometric methods for antimicrobial susceptibility testing of clinical isolates of the Nocardia asteroides complex.
- Comparison of the agar dilution, tube dilution, and broth microdilution susceptibility tests for determination of teicoplanin MICs.