Comparison of a New, Affordable Flow Cytometric Method and the Manual Magnetic Bead Technique for CD4 T-Lymphocyte Counting in a Northern Nigerian Setting
AUTOR(ES)
Imade, Godwin E.
FONTE
American Society for Microbiology
RESUMO
We compared two techniques for CD4 T-lymphocyte counting: flow cytometry (Cyflow) and magnetic beads (Dynabead). Similar results with good correlation were obtained from the 40 adult blood samples counted (P = 0.057, r = 0.93). The Cyflow technique is more precise and cost-effective than the Dynabead method ($3 to $5 versus $12 to $22 per test, respectively), since as many as 200 samples can be measured per day.