Comparison of Kodak Surecell Chlamydia Test Kit with culture for the diagnosis of chlamydial conjunctivitis in infants.
AUTOR(ES)
Hammerschlag, M R
RESUMO
The accuracy of the Surecell Chlamydia Test Kit (Kodak Clinical Products, Rochester, N.Y.) in detecting neonatal conjunctival infection caused by Chlamydia trachomatis was determined by comparison of this enzyme immunoassay with the isolation of C. trachomatis in tissue culture. Kodak Surecell is a rapid monoclonal antibody-based membrane capture enzyme immunoassay which can be processed in the office of a physician. The sensitivity and specificity compared to culture in detecting C. trachomatis in conjunctival specimens from infants with conjunctivitis were 93 and 96%, respectively. The test does not require specialized equipment or trained personnel and would be ideal for physicians who see low numbers of infants with possible chlamydial conjunctivitis in their offices.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=267949Documentos Relacionados
- Comparison of enzyme immunoassay and culture for diagnosis of chlamydial conjunctivitis and respiratory infections in infants.
- Comparison of two enzyme immunoassays to culture for the diagnosis of chlamydial conjunctivitis and respiratory infections in infants.
- Comparison of a chemiluminometric immunoassay with culture for diagnosis of chlamydial infections in infants.
- Detection of herpes simplex virus by the Kodak SureCell Herpes Test.