Detection of West Nile Virus (WNV)-Specific Immunoglobulin M in a Reference Laboratory Setting during the 2002 WNV Season in the United States
AUTOR(ES)
Prince, Harry E.
FONTE
American Society for Microbiology
RESUMO
Between 1 June and 31 December 2002, 30,677 serum samples and 4,554 cerebrospinal fluid (CSF) samples were tested for West Nile virus (WNV)-specific immunoglobulin M (IgM) by an in-house enzyme-linked immunosorbent assay (ELISA); 1,481 serum samples (4.8%) and 345 CSF samples (7.6%) were positive for WNV IgM. Positive samples were forwarded to public health service laboratories (PHSLs) for further testing. PHSLs supplied results from their WNV IgM ELISAs for 654 samples; 633 (97%) were positive. PHSLs supplied WNV plaque reduction neutralization test results for 128 samples; 123 (96%) were positive. WNV IgM seroconversion and seroreversion trends were evaluated for 749 patients who each provided two serum samples that were tested during the study period. Of 574 patients whose first serum sample was IgM negative, 41 (7%) seroconverted (the second serum sample was IgM positive); of 175 patients whose first serum sample was IgM positive, 22 (13%) seroreverted (the second serum sample was IgM negative). The seroreversion rate was directly proportional to the time between serum sample collection; whereas only 1% of patients whose sera were collected <20 days apart showed seroreversion, 54% of patients whose sera were collected >60 days apart showed seroreversion. Conversion and reversion trends for CSF were evaluated for 68 patients. Of 54 patients whose first CSF specimen was IgM negative, 9 (17%) converted; none of 14 patients whose first CSF specimen was IgM positive reverted. Concomitant detection of WNV IgM in serum and CSF was assessed for 1,188 patients for whom paired serum and CSF specimens were available; for all 130 patients for whom IgM was detectable in CSF, IgM was also detectable in serum. These findings show that an in-house WNV IgM ELISA accurately identifies patients with WNV infection, document WNV IgM conversion and reversion trends, and demonstrate that WNV IgM detection in CSF is accompanied by WNV IgM detection in serum.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=193906Documentos Relacionados
- Performance Characteristics of an In-House Assay System Used To Detect West Nile Virus (WNV)-Specific Immunoglobulin M during the 2001 WNV Season in the United States
- Evaluation of a Diagnostic Algorithm Using Immunoglobulin M Enzyme-Linked Immunosorbent Assay To Differentiate Human West Nile Virus and St. Louis Encephalitis Virus Infections during the 2002 West Nile Virus Epidemic in the United States
- Performance of Immunoglobulin G (IgG) and IgM Enzyme-Linked Immunosorbent Assays Using a West Nile Virus Recombinant Antigen (preM/E) for Detection of West Nile Virus- and Other Flavivirus-Specific Antibodies
- Detection of Anti-West Nile Virus Immunoglobulin M in Chicken Serum by an Enzyme-Linked Immunosorbent Assay
- Environmental and social determinants of human risk during a West Nile virus outbreak in the greater Chicago area, 2002