Determinación simultánea de Cr, Ni y V en orina mediante et aas
AUTOR(ES)
Álvarez, Maria A., Hermida, Jeymi
FONTE
Química Nova
DATA DE PUBLICAÇÃO
2011
RESUMO
A procedure for the simultaneous determination of Cr, Ni, and V in urine by electrothermal atomic absorption spectrometry (ET AAS) was optimized by factorial design, and performed at a pyrolysis and atomization temperatures of 1300 and 2500 ºC, respectively, using 15 µg de Mg(NO3)2 as chemical modifier. Characteristics mass of 14, 6 and 220 ρg and detection limits of the method of 0.07, 0.38 and 0.75 µg L-1 were obtained for Cr, Ni and V respectively. The methodology was validated using a Liphochek Urine Metals Control sample (Bio-Rad) (P=0.05). The methodology was applied to samples of voluntary Venezuelan people, not environmentally exposed to specific emissions, and results ranging from < LOD-1.1 and 1.3-3.3 µg L-1 was observed for Cr and V, respectively, and not detectable levels for Ni.
Documentos Relacionados
- Fotoluminescência de SrTiO3 dopado com Al, Y, Cr, V e Nb.
- Metodos de pre-concentração para determinação simultanea de Cr, Mn, Fe, Co, Ni, Cu, Zn, Hg e Pb por fluorescencia de raios-X
- Distribuição de Ba, Co, Cr, Cu, Mn, Ni, V e Zn nas frações granulométricas de um Latossolo submetido à adição de lodo de esgoto.
- Uptake of Co, Cr, Ni and Cu by Pyrite in a tropical marine environment
- Adsorção e dessorção de Cd, Cr, Ni e Pb em solos saturados na capacidade máxima de adsorção destes metais pesados