Determination of Trimethoprim-Sulfamethoxazole Resistance in Streptococcus pneumoniae by Using the E Test with Mueller-Hinton Agar Supplemented with Sheep or Horse Blood May Be Unreliable
AUTOR(ES)
Lovgren, M.
FONTE
American Society for Microbiology
RESUMO
An international, multicenter study compared trimethoprim-sulfamethoxazole MICs for 743 Streptococcus pneumoniae isolates (107 to 244 isolates per country) by E test, using Mueller-Hinton agar supplemented with 5% defibrinated horse blood or 5% defibrinated sheep blood, with MICs determined by the National Committee for Clinical Laboratory Standards broth microdilution reference method. Agreement within 1 log2 dilution and minor error rates were 69.3 and 15.5%, respectively, on sheep blood-supplemented agar and 76.9 and 13.6%, respectively, with horse blood as the supplement. Significant interlaboratory variability was observed. E test may not be a reliable method for determining the resistance of pneumococci to trimethoprim-sulfamethoxazole.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=84212Documentos Relacionados
- Selection of a reference lot of Mueller-Hinton agar.
- Use of Mueller-Hinton Agar as Amylase Testing Medium
- Evaluation of Mueller-Hinton agar for disk diffusion susceptibility tests.
- Effect of refrigerated storage on cefaclor in Mueller-Hinton agar.
- False susceptibility of enterococci to aminoglycosides with blood-enriched Mueller-Hinton agar for disk susceptibility testing.