Disinfection of Water Containing Natural Organic Matter by Using Ozone-Initiated Radical Reactions

AUTOR(ES)
FONTE

American Society for Microbiology

RESUMO

Ozone is widely used to disinfect drinking water and wastewater due to its strong biocidal oxidizing properties. Recently, it was reported that hydroxyl radicals (·OH), resulting from ozone decomposition, play a significant role in microbial inactivation when Bacillus subtilis endospores were used as the test microorganisms in pH controlled distilled water. However, it is not yet known how natural organic matter (NOM), which is ubiquitous in sources of drinking water, affects this process of disinfection by ozone-initiated radical reactions. Two types of water matrix were considered for this study. One is water containing humic acid, which is commercially available. The other is water from the Han River. This study reported that hydroxyl radicals, initiated by the ozone chain reaction, were significantly effective at B. subtilis endospore inactivation in water containing NOM, as well as in pH-controlled distilled water. The type of NOM and the pH have a considerable effect on the percentage of disinfection by hydroxyl radicals, which ranged from 20 to 50%. In addition, the theoretical \documentclass[12pt]{minimal} \usepackage{wasysym} \usepackage{amsmath} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} \begin{equation*}\overline{C}\end{equation*}\end{document}T value of hydroxyl radicals for 2-log B. subtilis removal was estimated to be about 2.4 × 104 times smaller than that of ozone, assuming that there is no synergistic activity between ozone and hydroxyl radicals.