Dissolution of stainless steel welding fumes in the rat lung: an x ray microanalytical study.
AUTOR(ES)
Anttila, S
RESUMO
The dissolution of stainless steel welding fumes produced by manual metal arc (MMA) and metal inert gas (MIG) techniques was studied by transmission electron microscopy and quantitative x ray microanalysis in the lungs of rats after inhalation exposure. Rats exposed to stainless steel fumes generated by MMA were found to have two particle populations of different behaviour in their lung tissue. The particles of the principal population (size 100-250 nm) dissolved in both alveolar macrophages and type 1 epithelial cells in about two months. Fast and slowly dissolving components of chromium, manganese, and iron were detected within these particles; they obviously represent different chemical compounds. The particles of the minor population (size 5-100 nm) showed no signs of dissolution during three months follow up. Rats exposed to stainless steel fumes generated by MIG had only one particle population in their lung tissue; they were similar to those of the minor population in the MMA/SS fumes and no solubility could be detected within three months.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=1007717Documentos Relacionados
- Exposure to stainless steel welding fumes and lung cancer: a meta-analysis.
- Stainless steel manual metal arc welding fumes in rats.
- X-Ray diffraction technique applied to study of residual stresses after welding of duplex stainless steel plates
- Innervation of alveolar walls in the human lung: an electron microscopic study.
- Relation between various chromium compounds and some other elements in fumes from manual metal arc stainless steel welding.