Experimental and theoretical study on workpiece temperature when tapping hardened AISI H13 using different cooling systems
AUTOR(ES)
Brandão, Lincoln Cardoso, Coelho, Reginaldo Teixeira, Malavolta, Alexandre Tácito
FONTE
Journal of the Brazilian Society of Mechanical Sciences and Engineering
DATA DE PUBLICAÇÃO
2010-06
RESUMO
Tapping operations on hardened steels have always been a great challenge. Dry machining and two cooling systems were used when tapping hardened AISI H13 (53 HRC). Embedded thermocouples were used for temperature measurement close to the thread diameter in the radial and axial direction. A FEA model was used to evaluate the heat "Q", and coefficient of convection "h". The lowest temperature peak occurred with the flooded system, followed by the MQL, and dry condition. The heat and coefficient of convection increased when using the flooded system, followed by the MQL, compared to the dry condition. Those values were also in accordance with early published works, using different techniques.
Documentos Relacionados
- Influence of HSM milling cutting parameters on tribological performance of hardened AISI H13 steel.
- Toroidal milling of hardened SAE H13 steel
- Estudo da influência do tratamento criogênico no aço AISI H13
- Tratamento superficial por refusão a laser em aços AISI H13 e AISI 420
- Estudo do comportamento tribológico do aço AISI H13 submetido a tratamento termoquímico de boretação