Flow boiling of water in a vertical tube at sub-atmospheric pressures
AUTOR(ES)
Barbosa Jr., Jader R., Cheah, Leong W., Hewitt, Geoffrey F.
FONTE
Journal of the Brazilian Society of Mechanical Sciences and Engineering
DATA DE PUBLICAÇÃO
2007-12
RESUMO
This paper describes some of the key experimental results and features obtained from a study on upward flow boiling of water in a vertical tube at sub-atmospheric pressures. The experiments were conducted at 250, 500 and 1000 mbar (abs) exit pressures. From the experimental results, several interesting features and effects were observed, namely, heat transfer coefficient maxima at around zero thermodynamic quality were observed for high inlet liquid subcoolings at low sub-atmospheric pressures, which were attributed to local thermal non-equilibrium instability (Jeglic and Grace, 1965). Such effects were also observed in boiling of pure hydrocarbons in vertical tubes (Kandlbinder, 1997; Urso et al., 2002) and were explained and explored quantitatively with a thermal non-equilibrium slug flow model (Barbosa and Hewitt, 2005) that associates vigorous bubble growth at sub-atmospheric pressures to the formation of large Taylor bubbles separated by subcooled liquid slugs.
Documentos Relacionados
- Subatmospheric closing pressures in individual microvessels of rats and frogs.
- Boiling of R-134a in horizontal mini tube
- Disinfection of woollen blankets in steam at subatmospheric pressure
- Fluctuating Atmospheric Pressures: A Novel Environmental Variant Observed in Submarines
- Lymph flow in sheep limbs during local exposure to subatmospheric pressure.