Lack of ciprofloxacin ototoxicity after repeated ototopical application.
AUTOR(ES)
Claes, J
RESUMO
The possible side effects of ototopically applied ciprofloxacin on inner ear function were investigated. The hearing function of pigmented guinea pigs was evaluated by daily frequency-specific evoked response audiometry after repeated application of the drug to both ears. Ciprofloxacin appeared to have no statistically significant effect on the hearing thresholds of the experimental animals.