Long-term Mortality Predictors in Patients with Small Aortic Annulus Undergoing Aortic Valve Replacement with a 19- or 21-mm Bioprosthesis
AUTOR(ES)
Oliveira, Jenny Lourdes Rivas de, Arnoni, Renato Tambellini, Santos, Magaly Arrais dos, Almeida, Antonio Flávio Sanchez, Issa, Mário, Arnoni, Antoninho Sanfins, Chaccur, Paulo, Souza, Luiz Carlos Bento de
FONTE
Braz. J. Cardiovasc. Surg.
DATA DE PUBLICAÇÃO
2016-09
RESUMO
Abstract Introduction: Replacement of the aortic valve in patients with a small aortic annulus is associated with increased morbidity and mortality. A prosthesis-patient mismatch is one of the main problems associated with failed valves in this patient population. Objective: To evaluate the long-term mortality predictors in patients with a small aortic annulus undergoing aortic valve replacement with a bioprosthesis. Methods: In this retrospective observational study, a total of 101 patients undergoing aortic valve replacement from January 2000 to December 2010 were studied. There were 81 (80.19%) women with a mean age of 52.81±18.4 years. Severe aortic stenosis was the main indication for surgery in 54 (53.4%) patients. Posterior annulus enlargement was performed in 16 (15.8%) patients. Overall, 54 (53.41%) patients underwent concomitant surgery: 28 (27.5%) underwent mitral valve replacement, and 13 (12.7%) underwent coronary artery bypass graft surgery. Results: Mean valve index was 0.82±0.08 cm2/m2. Overall, 17 (16.83%) patients had a valve index lower than 0.75 cm2/m2, without statistical significance for mortality (P=0.12). The overall 10-year survival rate was 83.17%. The rate for patients who underwent isolated aortic valve replacement was 91.3% and 73.1% (P=0.02) for patients who underwent concomitant surgery. In the univariate analysis, the main predictors of mortality were preoperative ejection fraction (P=0.02; HR 0.01) and EuroSCORE II results (P=0.00000042; HR 1.13). In the multivariate analysis, the main predictors of mortality were age (P=0.01, HR 1.04) and concomitant surgery (P=0.01, HR 5.04). Those relationships were statistically significant. Conclusion: A valve index of < 0.75 cm2/m2 did not affect 10-year survival. However, concomitant surgery and age significantly affected mortality.
Documentos Relacionados
- Aortic valve replacement with frame-mounted autologous fascia lata. Long-term results.
- Long-term results of pulmonary autograft for aortic valve replacement.
- Immediate and long-term results of aortic valve replacement with University of Cape Town aortic valve prosthesis
- Aortic valve replacement in the elderly. Risk factors and long-term results.
- Mitral valve replacement with Alvarez prosthesis: long-term results