Medidas de indicadores de estresse oxidativo e de remodelamento cardíaco em camundongos expostos à poluição atmosférica ambiental durante o desenvolvimento embrionário e pós-natal / Measurements of oxidative stress indicators and of cardiac remodeling in mice exposed to urban air pollution during embrionary and postnatal development.

AUTOR(ES)
DATA DE PUBLICAÇÃO

2007

RESUMO

I t is well known that air pollution exposure in São Paulo can elicit cardiovascular injuries in humans and experimental animals and that children and fetuses appear to be particularly vulnerable. However, the mechanisms involved in this cardiovascular damage are not well understood. It has been suggested that the oxidative stress generated by air pollution exposure can trigger tissue injury. There is evidence supporting the idea that injury caused by lipid peroxidation may be related to the causes of several cardiovascular diseases. The aim of this study was to investigate the effects of prenatal and postnatal exposure to urban air pollution on the myocardium lipid peroxidation levels of adult mice. Myocardium lipid peroxidation was determined by the TBA method and by the detection of 15-F2t-isoprostan by immunohistochemical technique. The animals were placed in two chambers: one received air that passed through an air filter (clean) and the second received ambient air (polluted), according to four different exposure procedures: 1) Clean (CC): prenatal and postnatal in the clean chamber (control group), 2) Polluted (PP): prenatal and posnatal in the polluted chamber, 3) Polluted-clean (PC): prenatal in the polluted and posnatal in the clean chamber and 4) Clean-polluted (CP): prenatal in the clean and posnatal in the polluted chamber. The concentration of of malondialdehyde (MDA, a indicator of lipid peroxidation) was higher in group PP compared to CC (p = 0.004) and to PC (p = 0.026), and was not different of group CP (p = 0.894). The values of MDA for groups PC and CP turned to be equal (p = 0.168). Interestingly, group PC had a higher value of MDA than group CC (p = 0.026). The volume fraction of myocardium with detection of 15-F2tisoprostane is higher in PC (p = 2.884x10-5), CP (p = 6.632x10-6) and PP (p = 5.45x10-8) than in CC. The value of PP in higher than those of PC and CP (p = 3.661x10-4 and 1.058x10-3, respectively), while the latter two were equal to each other (p = 0.624). ). The mean ratio of arterioles wiht lumen area between 200 and 1000?m² to the total number of vessels in each group was higher in PP than in CC and PC (p=0.0387 and p=0.0362, respectively). These results, which suggest that exposure to air pollution is associated to higher levels of lipid peroxidation in the myocardium, are compared to other results previously published about respiratory and reproductive alterations related to pollution. Interestingly, the increased levels of lipid peroxidation in the PC group gives evidence that the prenatal exposure to urban air pollution can be linked to cardiovascular effects in adult life.

ASSUNTO(S)

embryonic and fetal development miocárdio peroxidação de lipídeos colágeno oxidative stress estresse oxidativo camundongos/crescimento &desenvolvimento lipid peroxidation mice/growth &development. collagen poluição do ar/efeitos adversos desenvolvimento embrionário e fetal air pollution/adverse effects myocardium

Documentos Relacionados