In a PWR nuclear power plant, the reactor pressure vessel (RPV) contains the fuel assemblies and reactor vessels internals and keeps the coolant at high temperature and high pressure during normal operation. The RPV integrity must be assured all along its useful life to protect the general public against a significant radiation liberation damage. One of the critical issues relative to the VPR structural integrity refers to the pressurized thermal shock (PTS) accident evaluation. To better understand the effects of this kind of event, a PTS experiment has been planned using an RPV prototype. The RPV material fracture behavior characterization in the ductile-brittle transition region represents one of the most important aspects of the structural assessment process of RPV's under PTS. This work presents the results of fracture toughness tests carried out to characterize the RPV prototype material behavior. The test data includes Charpy energy curves, T0 reference temperatures for definition of master curves, and fracture surfaces observed in electronic microscope. The results are given for the vessel steel in the "as received" and normalized conditions. This way, the influence of the normalizing treatment on the fracture properties of the steel could be evaluated.
Documentos Relacionados
- Influência da austenita retida no crescimento de trincas curtas superficiais por fadiga em camada cementada de aço SAE 8620
- Normalizing heat treatment effect on low alloy steel weld metals
- Influence of phosphorus content and quenching/tempering temperatures on fracture toughness and fatigue life of SAE 5160 steel
- Influence of Temperature on Mechanical Properties, Fracture Morphology and Strain Hardening Behavior of a 304 Stainless Steel
- Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wires