Performance of the APTIMA Combo 2 Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Female Urine and Endocervical Swab Specimens
AUTOR(ES)
Gaydos, C. A.
FONTE
American Society for Microbiology
RESUMO
The greater sensitivity of nucleic acid amplification tests (NAATs) for Chlamydia trachomatis and Neisseria gonorrhoeae permits the use of urine and other noninvasive specimens, which can increase the reach and decrease the costs of public health screening programs aimed at controlling these infections. This study evaluated the performance of the APTIMA Combo 2 assay, a multiplex assay based on the transcription-mediated amplification reaction, for the simultaneous detection of both pathogens in endocervical swab and urine specimens from females. Combo 2 assay results were compared with patient infected status, which were available by using other commercial NAATs. Sensitivity and specificity for C. trachomatis were 94.2 and 97.6%, respectively, in swabs and 94.7 and 98.9%, respectively, in first-catch urine (FCU). Sensitivity and specificity for N. gonorrhoeae were 99.2 and 98.7%, respectively, in swabs and 91.3 and 99.3%, respectively, in FCU. The assay reliably detected both infections in coinfected patients. The Combo 2 assay can be recommended for use with endocervical swab and urine specimens from females, especially for screening tests for asymptomatic women in sexually transmitted disease surveillance programs. This Food and Drug Administration-cleared assay can be a useful tool in efforts to reduce the prevalence and incidence of C. trachomatis and N. gonorrhoeae infections in sexually active women and to prevent their costly and serious sequelae.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=149571Documentos Relacionados
- Comparison of the APTIMA CT and GC Assays with the APTIMA Combo 2 Assay, the Abbott LCx Assay, and Direct Fluorescent-Antibody and Culture Assays for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae
- Multicenter Evaluation of the BDProbeTec ET System for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Urine Specimens, Female Endocervical Swabs, and Male Urethral Swabs
- Comparison of the PACE 2 Assay, Two Amplification Assays, and Clearview EIA for Detection of Chlamydia trachomatis in Female Endocervical and Urine Specimens
- Evaluation of the Abbott LCx Assay for Detection of Neisseria gonorrhoeae in Endocervical Swab Specimens from Females
- Performance of the MagNA Pure LC Robot for Extraction of Chlamydia trachomatis and Neisseria gonorrhoeae DNA from Urine and Swab Specimens