Relative Sensitivity of Gel Diffusion, Complement Fixation, and Immunoelectroosmophoresis Tests for Detection of Hepatitis-Associated Antigen and Antibody

AUTOR(ES)
RESUMO

The immunoelectroosmophoresis (IEOP) test was compared with gel diffusion and complement fixation (CF) tests for sensitivity in detecting hepatitis-associated antigen (HAA) in the sera of hepatitis patients, for titration of HAA, and for detection of antibody to HAA. The IEOP test was found to be slightly more sensitive than either gel diffusion or CF tests for detection of antigen in the patients' sera. Titers of HAA demonstrated by IEOP were higher than those seen in gel diffusion tests but lower than CF titers. The gel diffusion test with an “enhancement” pattern was found to be more reliable than the other two procedures for detection of low levels of anti-HAA, due to the greater inhibitory effect of an antigen excess in the IEOP system and the possible masking of low levels of antibody by anticomplementary activity in the CF test system. Staining of immunoprecipitates in the IEOP test contributed little to the sensitivity of the test for detection of HAA.

Documentos Relacionados