Strength-duration characteristics of myelinated and non-myelinated bulbospinal axons in the cat spinal cord.
AUTOR(ES)
West, D C
RESUMO
Strength-duration characteristics for the stimulation of 131 raphespinal and reticulospinal axons in the spinal cord were determined using two types of stimulating electrode. Conduction velocity of these fibres ranged from 0.86 to 63 m/s. With silver wire (250 micron diameter) stimulating electrodes, chronaxies were: 0.18 +/- 0.06 ms for axons conducting between 16 and 63 m/s, 0.4 +/- 0.22 ms for axons conducting between 5 and 15 m/s and 2.06 +/- 0.79 ms for those with conduction velocity less than 5 m/s. There was an inverse relationship between chronaxie and conduction velocity. Rheobase values ranged from 7.4 to 400 microA but were independent of conduction velocity. Chronaxies obtained with wire electrodes were compared with those from stimulation of the same fibre through saline-filled micropipettes (2-12 micron tip diameter). Rheobase values with the micropipettes ranged from 1.6 to 20 microA, indicating a close proximity of the pipette to the axon. For these axons, chronaxies from metal wire electrodes ranged from 0.12 to 2.4 ms and for micropipettes from 0.04 to 0.65 ms. In almost all cases, chronaxies for micropipette stimulation were lower than those for metal wire electrodes. Furthermore, with micropipettes chronaxies were independent of conduction velocity. The results are shown to be related to differences in time constant of the activated region of axon and charge requirements of threshold activation. The two stimulating conditions, i.e. micro-electrodes compared with wire electrodes, are analogous to the theoretical point stimulated cable and uniformly polarized membrane cases. The results are discussed in relation to the possibility of determination of fibre type from stimulation characteristics. A distinction between chronaxies of myelinated and non-myelinated fibres can be made using wire electrodes of 250 micron diameter, but not with micro-stimulation, as with micropipettes (2-12 micron diameter).
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=1199093Documentos Relacionados
- The strength-duration relationship for excitation of myelinated nerve: computed dependence on membrane parameters.
- Nuclear population changes in degenerating non-myelinated nerves
- Strength-duration curve: a measure for assessing sensory deficit in peripheral neuropathy.
- Sodium currents in Schwann cells from myelinated and non-myelinated nerves of neonatal and adult rabbits.
- The effects of electrical stimulation of myelinated and non-myelinated vagal fibres on heart rate in the rabbit.