Surface modification of titanium by plasma nitriding
AUTOR(ES)
Kapczinski, Myriam Pereira
DATA DE PUBLICAÇÃO
2010
RESUMO
A systematic investigation was undertaken on commercially pure titanium submitted to plasma nitriding. Thirteen different sets of operational parameters (nitriding time, sample temperature and plasma atmosphere) were used. Surface analyses were performed using X-ray diffraction, nuclear reaction and scanning electron microscopy. Wear tests were done with stainless steel Gracey scaler, sonic apparatus and pin-on-disc machine. The obtained results indicate that the tribological performance can be improved for samples treated with the following conditions: nitriding time of 3 h; plasma atmosphere consisting of 80%N2+20%H2 or 20%N2+80%H2; sample temperature during nitriding of 600 or 800 °C.
ASSUNTO(S)
plasma nitriding titanio tribologia tribology titanium implantacao : dentes nitretação a plasma dental implants física
ACESSO AO ARTIGO
http://hdl.handle.net/10183/19664Documentos Relacionados
- Surface modification of titanium by plasma nitriding
- Surface Modification of Polymeric Materials by Plasma Treatment
- Proliferation of human periodontal ligament mesenchymal cells on polished and plasma nitriding titanium surfaces
- Evaluation of titanium implants with surface modification by laser beam: biomechanical study in rabbit tibias
- Acquired Properties Comparison of Solid Nitriding, Gas Nitriding and Plasma Nitriding in Tool Steels