Digital Radiography
Mostrando 1-12 de 85 artigos, teses e dissertações.
-
1. Comparison of the Accuracy of Digital Radiography with Conventional Radiography and Visual Examination in the Detection of Permanent Teeth Interproximal Caries
Abstract Objective: To compared the accuracy of digital radiography in the diagnosis of interproximal caries in permanent teeth with conventional radiography and visual examination. Material and Methods: In this descriptive-analytical study, 78 human premolars, which seem normal in primary examination, are mounted on the plaster in a pair-wise manner and t
Pesqui. Bras. Odontopediatria Clín. Integr.. Publicado em: 02/09/2019
-
2. Digital radiography as an alternative method in the evaluation of bone density in uremic rats
RESUMO Introdução: A radiografia digital (RxD) pode representar uma alternativa adequada para investigar o distúrbio mineral e ósseo (DMO) e a perda de densidade óssea (DO) em modelos de roedores da doença renal crônica (DRC). O objetivo deste estudo foi utilizar a RxD para avaliar a DO em ratos com DRC, e avaliar a correlação entre os achados da R
J. Bras. Nefrol.. Publicado em: 08/08/2019
-
3. Penetration of bioceramic and epoxy-resin endodontic cements into lateral canals
Abstract: The aim of the present study was to assess the penetration capacity of two endodontic cements, Endosequence BC Sealer and AH Plus, in artificial lateral canals. Twenty-six two-rooted, maxillary first premolars were instrumented to size 40.06 using K3 files. In each root, six lateral canals of two diameters (0.06 and 0.10 mm) were created with a wor
Braz. oral res.. Publicado em: 27/05/2019
-
4. Addition of zirconium oxide to Biodentine increases radiopacity and does not alter its physicochemical and biological properties
Abstract Objectives: To evaluate the radiopacity of Biodentine (BD) and BD associated with 15% calcium tungstate (BDCaWO4) or zirconium oxide (BDZrO2), by using conventional and digital radiography systems, and their physicochemical and biological properties. Materials and Methods: Radiopacity was evaluated by taking radiographs of cement specimens (n=8) u
J. Appl. Oral Sci.. Publicado em: 01/04/2019
-
5. Robust pulmonary segmentation for chest radiography, combining enhancement, adaptive morphology and innovative active contours
Abstract Introduction Statistical data reveal that approximately 140 million radiological exams are performed annually in Brazil. These exams are designed to detect and to analyze fractures, caused by different types of trauma; as well as, to diagnose pathologies such as pulmonary diseases. For better visualization of those lesions or abnormalities, method
Res. Biomed. Eng.. Publicado em: 13/09/2018
-
6. Absorbed doses in salivary and thyroid glands from panoramic radiography and cone beam computed tomography
Abstract Introduction: Panoramic radiography and cone beam computed tomography (CBCT) are very important in the diagnosis of oral diseases, however patients are exposed to the risk of ionizing radiation. This paper describes our study aimed at comparing absorbed doses in the salivary glands and thyroid due to panoramic radiography and CBCT and estimating ra
Res. Biomed. Eng.. Publicado em: 15/02/2018
-
7. Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study
OBJECTIVES: This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph. METHODS: Three different image acquisition protocols were established for each cone beam computer tomography apparatus, and three clinical situations were simulated in an ex vivo fresh p
Clinics. Publicado em: 2017-11
-
8. The Accuracy of Digital Radiography for Diagnosis of Fishbone Foreign Bodies in the Throat
Abstract Introduction Some patients with a fishbone as a foreign body of difficult diagnosis may require further investigations. Generally, radiography is used as the first choice for finding the fishbone. Objective The objective of this study is to determine the accuracy of digital radiography for diagnosis of fishbone foreign body in the throat Method
Int. Arch. Otorhinolaryngol.. Publicado em: 2017-09
-
9. Comparison of Cone-Beam Computed Tomography and Intraoral Radiography in Detection of Recurrent Caries under Composite Restorations
Resumo A causa mais comum de falha das cáries dentais são as cáries secundárias. Este estudo objetivou comparar a acurácia diagnóstica da radiografia intraoral digital e convencional com a tomografia computadorizada de feixe cônico (TCFC) para a detecção de cáries recorrentes em torno restaurações com compósitos. Cavidades mésio-oclusais-distai
Braz. Dent. J.. Publicado em: 2017-02
-
10. 2D and 3D imaging of the relationship between maxillary sinus and posterior teeth
Aim: To compare the qualitative and quantitative information yielded by imaging modalities on the evaluation of the relationship between the maxillary sinus and the apices of posterior teeth.
Methods: Three oral radiologists examined 109 panoramic radiographs and cone-beam computed tomography (CBCT) images
Braz. J. Oral Sci.. Publicado em: 2015-06
-
11. Analysis of the reproducibility of the gray values and noise of a direct digital radiography system
The aim of this study was to evaluate the reproducibility of the gray values and noise of a direct digital radiography system (Visualix eHD) for various exposure times and analyzed regions. To obtain radiographic images in a standardized manner, the digital sensor of the system and a stepwedge were positioned in a phantom at a focus-film distance of 30 cm in
Braz. oral res.. Publicado em: 26/05/2015
-
12. Filling of simulated lateral canals with gutta-percha or thermoplastic polymer by warm vertical compaction
The aim of this study was to evaluate the ability of gutta-percha and a thermoplastic synthetic polymer (Resilon) to fill simulated lateral canals, using warm vertical compaction. Forty-five single-rooted human teeth were prepared using the rotary crown-down technique. Artificial lateral canals were made at 2, 5, and 8 mm from the working length (WL) in each
Braz. oral res.. Publicado em: 10/04/2015