Fluxgate
Mostrando 1-12 de 12 artigos, teses e dissertações.
-
1. Microssensores magnéticos tipo fluxgate planar utilizando ligas de NiFe eletrodepositadas / Planar microfluxgates using NiFe eletrodeposited cores.
This work present the development of fluxgate magnetic field sensors based on planar technology. The material for the core of the device is based on early works that determined the best NiFe electrodeposition parameters for this application. Functional devices were created proving the usability of the alloy. Also 4 new layouts were proposed in order to build
Publicado em: 2010
-
2. Optimization of the magnetic properties of materials for fluxgate sensors
A study was made of the variation of the magnetic properties of cobalt-based alloys using different compositions of CoFeSiB and CoFeSiBCr systems, which were produced by the melt-spinning technique and some of them subjected to a stress annealing treatment. A comparative study of core geometry and supporting material was also performed in order to obtain low
Materials Research. Publicado em: 2008-06
-
3. Configurações alternativas para magnetômetros ''fluxgate'' com núcleo amorfo
Magnetômetros fluxgates são amplamente usados em medidas do campo magnético de baixa intensidade, principalmente para finalidades associadas a observações geomagnéticas, prospecção mineral e pesquisa espacial, por causa do consumo pequeno, nível de ruído baixo, faixa dinâmica ampla e grande sensibilidade. Aplicações recentes de magnetismo mole,
Revista Brasileira de Geofísica. Publicado em: 2007-06
-
4. Ligas magnéticas NiFe e NiFeCo eletrodepositadas, voltadas para aplicações em micro-sensores magnéticos tipo fluxgate planar / Electrodeposited NiFe and NiFeCo films for planar fluxgate sensors
This work presents the results about the fabrication and characterization of thin films of NiFe and NiFeCo alloys. The attempts to construct the planar fluxgate are also presented. Galvanostatic electrodeposition using an electrolytic solution containing Ni and Fe was used: NiSO4 (0,7 mol/l); NiCl2 (0,02 mol/l); FeSO4 (0,03 mol/l); H3BO3 (0,4 mol/l) and C7H5
Publicado em: 2007
-
5. Analysis of geomagnetic storm variations and count-rate of cosmic ray muons recorded at the Brazilian southern space observatory
Neste trabalho apresentamos uma análise das variações geomagnéticas e contagem de raios cósmicos (muons) detectados no Observatório Espacial do Sul - OES/CRS/INPE - MCT (29.43ºS, 53.80ºW), em São Martinho da Serra, RS, durante o mês de Novembro de 2004. As medidas das variações geomagnéticas são realizadas através de um magnetômetro fluxgate
Revista Brasileira de Geofísica. Publicado em: 2007
-
6. Desenvolvimento e aplicaÃÃo de magnetÃmetro fluxgate de baixo ruÃdo com nÃcleo amorfo.
MagnetÃmetros "fluxgates" sÃo largamente utilizados nas medidas de campos magnÃticos fracos, principalmente nas observaÃÃes geomagnÃticas, prospeÃÃo mineral e pesquisa espacial, devido ao seu baixo consumo, baixo nÃvel de ruÃdo, robustez, ampla faixa dinÃmica e boa sensibilidade. A utilizaÃÃo do magnetismo macio em ligas amorfas estimulou o trab
Publicado em: 2006
-
7. DEVELOPMENT AND CHARACTERIZATION OF A FIELD MAGNETIC TRANSDUCER BASED ON GIANT MAGNETOIMPEDANCE EFFECT / DESENVOLVIMENTO E CARACTERIZAÇÃO DE UM TRANSDUTOR MAGNÉTICO BASEADO NO EFEITO DA MAGNETOIMPEDÂNCIA GIGANTE
In this dissertation, it is proposed the design of a magnetic field to voltage transducer based on the Giant Magnetoimpedance phenomenon (GMI), characterized by an innovative geometric configuration. In order to attain the best near-field sensibility and far-field immunity, the transducer`s sensitive element and electronic circuit were planned and implemente
Publicado em: 2005
-
8. Electromagnetic induction studies to deep structures characterization on the southern border of São Francisco craton / Estudo da indução eletromagnética na caracterização de estruturas profundas sob a borda sul do cráton de São Francisco
Dados magnetotelúricos de banda larga e de longo período foram coletados ao longo de um perfil NS de 160 km de extensão e de um perfil ENE-WSW de 230 km de extensão na borda sul do Cráton arqueano-proterozóico do São Francisco (sudeste do Brasil) e cinturões de dobramento neoproterozóicos adjacentes. Modelos 2D de estruturas mínimas de resistividad
Publicado em: 2004
-
9. MagnetÃmetro fluxgate para satÃlites cientÃficos.
O magnetÃmetro fluxgate tem importante papel na detecÃÃo, medida e investigaÃÃo do campo magnÃtico da Terra. ProspecÃÃo mineral, testes nÃo destrutivos de materiais, avaliaÃÃo das interferÃncias nos enlaces de radiocomunicaÃÃo, controle de atitude de aeronaves, sÃo alguns das suas atuais utilizaÃÃes. Os magnetÃmetros de nÃcleo saturado ou
Publicado em: 2000
-
10. Projeto e construção de um sensor magnetico do tipo fluxgate
The aim of this work is to study magnetic sensors like fluxgate and the construction of a fluxgate magnetometer using modulation by pulse width method. This method alIows that the magnetometric system, in open loop, be compatible with digital systems of measurement, preventing, in this way, a possible conversion AD. The magnetometer built is composed of a co
Publicado em: 1999
-
11. Estudos de micropulsacoes geomagneticas PC3-5 em latitudes muito baixas, no Brasil / PC3-5 study of geomagnetic micropulsations at very low latitude, in Brazil
Neste estudo, procurou-se compreender os mecanismos de geracao e modos de propagacao de micropulsacoes Pc3-5, em latitudes muito baixas e equatoriais. Usou-se dados simultaneos observados com uma cadeia de 10 estacoes geomagneticas. no territorio brasileiro, dispondo de magnetometros ""fluxgate"" de alta sensibilidade. Utilizou-se o metodo de estimacao espec
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 199812
-
12. Estudos de micropulsacoes geomagneticas PC3-5 em latitudes muito baixas, no Brasil / PC3-5 study of geomagnetic micropulsations at very low latitude, in Brazil
Neste estudo, procurou-se compreender os mecanismos de geracao e modos de propagacao de micropulsacoes Pc3-5, em latitudes muito baixas e equatoriais. Usou-se dados simultaneos observados com uma cadeia de 10 estacoes geomagneticas. no territorio brasileiro, dispondo de magnetometros ""fluxgate"" de alta sensibilidade. Utilizou-se o metodo de estimacao espec
Publicado em: 1998