Gingival Retraction
Mostrando 1-7 de 7 artigos, teses e dissertações.
-
1. Effect of Gingival Retraction Method to Lateral Gingival Displacement Width
Abstract Objective: To analyze the efficacy of retraction cord with a hemostatic agent in comparison with retraction paste on lateral gingival displacement, to achieve the success of fixed dental prostheses (FDP). Material and Methods: Test samples included 32 teeth that required treatment with metal-porcelain FDP at RSKGM FKG Universitas Indonesia. Impres
Pesqui. Bras. Odontopediatria Clín. Integr.. Publicado em: 13/01/2020
-
2. Effect of a cordless retraction paste on titanium surface: a topographic, chemical and biocompatibility evaluation
Good exposure of the preparation margins and haemostasis in the sulcular gingiva are necessary for accurate impressions to produce precise restorations. The use of cordless retraction paste material in implant dentistry is a relatively novel application. However, few studies have been conducted on the use of retraction pastes and their possible interaction w
Braz. oral res.. Publicado em: 2013-06
-
3. Verificação da presença e abertura dos túbulos dentinários em pacientes portadores de recessão gengival com e sem hipersensibilidade dentinária por microscopia eletrônica de varredura
O objetivo deste estudo foi verificar a presença e abertura dos túbulos dentinários em pacientes portadores de recessão gengival com e sem hipersensibilidade dentinária por microscopia eletrônica de varredura. Foram selecionados 11 pacientes onde foram avaliados os dentes sensíveis e não sensíveis, sendo constituídos dois grupos (n = 11), onde GE e
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 20/06/2011
-
4. Effect of a cordless retraction paste material on implant surfaces: an in vitro study
Cordless retraction paste material for gingival retraction in implant dentistry has recently become of interest to the clinician. However, few studies have been conducted on the use of retraction pastes and their possible interaction with implant surfaces. This in vitro study evaluated the effect of a cordless retraction paste material, Expasyl® (Acteon), o
Brazilian Oral Research. Publicado em: 2011-12
-
5. Effects of sulfur-based hemostatic agents and gingival retraction cords handled with latex gloves on the polymerization of polyvinyl siloxane impression materials
OBJECTIVES: This study investigated the possible interactions between three addition silicone materials (Express®, Aquasil Ultra® and Adsil®), three hemostatic agents (ferric sulfate, StatGel FS®; aluminum sulfate, GelCord®; and aluminum chloride, Hemostop®) and gingival retraction cords previously handled with latex gloves to determine whether direct
Journal of Applied Oral Science. Publicado em: 2011-12
-
6. Effect of conventional and experimental gingival retraction solutions on the tensile strength and inhibition of polymerization of four types of impression materials
In the present study, two types of tests (tensile strength test and polymerization inhibition test) were performed to evaluate the physical and chemical properties of four impression materials [a polysulfide (Permlastic), a polyether (Impregum), a condensation silicone (Xantopren) and a polyvinylsiloxane (Aquasil),3; when polymerized in contact with of one c
Journal of Applied Oral Science. Publicado em: 2008-08
-
7. Avaliação clinica de terapia periodontal cirurgica utilizando aparelho ultra-sonico associado a escovação com tetracilina a 40%
The goal ofthe present investigation was to compare, clinically, two surgi cal procedures for root detoxification. Twenty patients diagnosed with adult periodontitis and showing at least four interproximal sites with a probing depth 5mm on anterior area were included. AlI patients received oral hygiene instruction and supragengival ultrasonic instrumentation
Publicado em: 2000