Impactors
Mostrando 1-10 de 10 artigos, teses e dissertações.
-
1. High Order Impact Elastic Analysis of Circular Thick Cylindrical Sandwich Panels Subjected to Multi-mass Impacts
Abstract This study dealt with the dynamic model of composite cylindrical sandwich panels with flexible cores and simply supported boundary conditions under low velocity impacts of multiple large or small masses using a new improved higher order sandwich panel theory (IHSAPT). In-plane stresses were considered for the core and face sheets. Formulation was ba
Lat. Am. j. solids struct.. Publicado em: 2015-12
-
2. Set of miniaturized structure used for manipulation of mixture. / Conjunto de estruturas miniaturizadas para manipulação de misturas.
Nowadays, mainly due to products miniaturization, engineering faces new horizons, which can be easily exemplified by the enhancement on nanotechnology development. Furthermore, not only environmental contamination but also environmental monitoring must be addressed in order to produce a systemic knowledge. Therefore, the aim of this work was to determine how
Publicado em: 2010
-
3. Human risk assessment for air pollution by passive biomonitoring: a case study in São Mateus do Sul, Paraná, Brazil / Avaliação do risco humano a poluentes atmosféricos por meio de biomonitoramento passivo: um estudo de caso em São Mateus do Sul, Paraná
In developing countries significant sources of air pollution may go undetected in areas that do not have qualified structure to measure air contaminants. In this context, simplified methods of measuring ambient particles, such as portable impactors and trace elements accumulate in tree barks, may provide information to identify areas influenced by source emi
Publicado em: 2009
-
4. DESIGN, NUMERICAL SIMULATION AND EXPERIMENTAL EVALUATION OF AN INERTIAL IMPACTOR USED TO COLLECT ATMOSPHERIC AEROSOLS / PROJETO, SIMULAÇÃO NUMÉRICA E TESTE EXPERIMENTAL DE UM IMPACTADOR INERCIAL EM CASCATA PARA AMOSTRAGEM DE AEROSSÓIS ATMOSFÉRICOS
Impactors are simple devices in which a sample flows of air and pollutants flow around an obstacle, called impaction plate. Particles with sufficient inertia will slip across the flow streamlines and impact on the obstacle. Particles with less inertia will follow the airflow away from the impaction surface. Inertial cascade impactors have more than one impac
Publicado em: 2005
-
5. AEROSOL CHARACTERIZATION IN A REGION WITH HIGH CONCENTRATION OF MINERAL SANDS. / CARACTERIZAÇÃO DE AEROSSÓIS EM UMA REGIÃO RICA EM AREIAS MONAZÍTICAS.
The main deposit of mineral sands in Brasil occur from the Rio Grande do Norte State to Rio de Janeiro State. The main commercial deposit is located in Buena, a village at São Francisco de Itabapoana, Rio de Janeiro State. In buena there is a plant that process minerals sands to obtain ilmenite, zirconite, rutile and monazite concentrates. This plant belong
Publicado em: 2003
-
6. The Abbreviated Impactor Measurement (AIM) Concept: Part II—Influence of Evaporation of a Volatile Component—Evaluation with a “Droplet-Producing” Pressurized Metered Dose Inhaler (pMDI)-Based Formulation Containing Ethanol as Cosolvent
The abbreviated impactor measurement (AIM) concept is a potential solution to the labor-intensive full-resolution cascade impactor (CI) methodology for inhaler aerosol aerodynamic particle size measurement. In this validation study, the effect of increasing the internal dead volume on determined mass fractions relating to aerodynamic particle size was explor
Springer US.
-
7. Aerodynamic particle size analysis of aerosols from pressurized metered-dose inhalers: Comparison of andersen 8-stage cascade impactor, next generation pharmaceutical impactor, and model 3321 aerodynamic particle sizer aerosol spectrometer
The purpose of this research was to compare three different methods for the aerodynamic assessment of (1) chloroflurocarbon (CFC)-fluticasone propionate (Flovent), (2) CFC-sodium cromoglycate (Intal), and (3) hydrofluoroalkane (HFA)-beclomethasone dipropionate (Qvar) delivered by pressurized metered dose inhaler. Particle size distributions were compared det
Springer-Verlag.
-
8. Precision of the all-glass impinger and the andersen microbial impactor for air sampling in solid-waste handling facilities.
A method was devised to determine the precision of the all-glass impinger and the Andersen six-stage microbial impactor over a wide range of aerosol concentrations like those found in facilities which process solid waste. Simultaneous samples were collected inside a municipal solid-waste recovery system, and the data were treated statistically to estimate th
-
9. The Abbreviated Impactor Measurement (AIM) Concept: Part 1—Influence of Particle Bounce and Re-Entrainment—Evaluation with a “Dry” Pressurized Metered Dose Inhaler (pMDI)-Based Formulation
The abbreviated impactor measurement concept is a potential improvement to the labor-intensive full-resolution cascade impactor methodology for inhaler aerosol aerodynamic particle size distribution (APSD) measurement by virtue of being simpler and therefore quicker to execute. At the same time, improved measurement precision should be possible by eliminatin
Springer US.
-
10. Effect of impact stress on microbial recovery on an agar surface.
Microbial stress due to the impaction of microorganisms onto an agar collection surface was studied experimentally. The relative recovery rates of aerosolized Pseudomonas fluorescens and Micrococcus luteus were determined as a function of the impaction velocity by using a moving agar slide impactor operating over a flow rate range from 3.8 to 40 liters/min y