Limiting Magnetic
Mostrando 1-12 de 42 artigos, teses e dissertações.
-
1. Alcoholmeter as a Simple and Accessible Way for Ethanol Determination in Alcohol-Based Hand Sanitizers
Expensive and complex methodologies are available to determine the ethanol concentration in alcohol gel samples. The aim of this article was to demonstrate that alcoholmeter could be used as an alternative method to determine ethanol in gel formulations. Alcohol gel samples were produced using: hydroxypropylmethylcellulose (HPMC), hydroxyethylcellulose (HEC)
J. Braz. Chem. Soc.. Publicado em: 2021-06
-
2. Is Femoral Version Associated with Changes in Hip Muscle Strength in Females with Symptomatic Femoroacetabular Impingement?
Resumo Objetivo O objetivo deste estudo foi avaliar a associação da anteversão femoral e da força dos músculos do quadril em indivíduos com síndrome do impacto femoroacetabular. Método Os ângulos de versão femoral descritos nas imagens de ressonância magnética articular e os testes isocinéticos foram avaliados retrospectivamente entre julho
Rev. bras. ortop.. Publicado em: 07/10/2019
-
3. Binary Micellar Solutions of Poly(Ethylene Oxide)-Poly(Styrene Oxide) Copolymers with Pluronic® P123: Drug Solubilisation and Cytotoxicity Studies
The non-commercial copolymers E45S8, E45S17 and their mixtures with Pluronic® P123 (E21P67E21) were studied as carriers of the model drug griseofulvin. Critical micelle concentration (cmc) (dye solubilisation method), drug solubilisation capacity (Scp and Sh) determined by ultraviolet-visible (UV-Vis) spectroscopy and 1H nuclear magnetic resonance (1H NMR)
J. Braz. Chem. Soc.. Publicado em: 2015-11
-
4. Development and test of a small resistive fault current limiting device based on Hg, Re-1223 and Sm-123 ceramics
Several reports describing Superconducting Fault Current Limiter (SFCL) containing members of the bismuth or yttrium ceramics were already described. However, none of these included the mercury and samarium cuprates. Consequently, we have conducted a study of a resistive-type superconductor fault current limiter based on Hg0.82Re0.18Ba2Ca2Cu3O8+d samples and
Mat. Res.. Publicado em: 03/06/2014
-
5. Glicólise do poli(3-hidroxibutirato) por via enzimática
Poly(3-hydroxybutyrate), PHB, is a polymer with broad potential applications because of its biodegradability and biocompatibility. However, its high crystallinity is a limiting factor for many applications. To overcome this drawback, one strategy currently employed involves the reduction of the molecular weight of PHB with the concomitant formation of end-fu
Quím. Nova. Publicado em: 2014-06
-
6. Catalisadores de Pt suportados, obtidos pelo método solgel : efeito do cério na atividade e estabilidade nas reações de reforma do metano
The effect of Ce as a structural and electronic promoter on the activity and stability of Pt catalysts supported on Al2O3 for methane reforming reactions were investigated to elucidate the metal-support interaction. Pt/Al2O3 and Pt/CeO2-Al2O3 catalysts were prepared by conventional method of wet impregnation on commercial supports and on CeO2- Al2O3 mixed ox
Publicado em: 2009
-
7. Magneto-tunelamento ressonante em super-redes de GaAs/AsGaAs
In this thesis we present three works in weakly coupled semiconductor superlattices of GaAs/AlGaAs. In the first work we present an investigation of the electric field domain configuration in the sequential tunneling regime in weakly coupled superlattices in the presence of a magnetic field applied parallel to the quantum well layers. We show that, for an ap
Publicado em: 2008
-
8. On hydromagnetic rotating flow of a dusty fluid near a pulsating plate
An initial value problem is solved for the motion of an incompressible viscous conducting fluid with embedded small inert spherical particles bounded by an infinite rigid non-conducting plate. Both the plate and the fluid are in a state of solid-body rotation with constant angular velocity about an axis normal to the plate. The unsteady flow is generated in
Computational & Applied Mathematics. Publicado em: 2008
-
9. Intramyocardial injection of autologous bone marrow cells as an adjunctive therapy to incomplete myocardial revascularization: safety issues
OBJECTIVES: To determine the safety of intramyocardial injection of autologous bone marrow cells in patients undergoing surgical myocardial revascularization (CABG) for severe coronary artery disease. INTRODUCTION: There is little data available regarding the safety profile of autologous bone marrow cells injected during surgical myocardial revascularization
Clinics. Publicado em: 2008
-
10. Polimetalates porphyrins with ruthenium phosphinics complex to application in homogeny catalyze, Non Linear Optic and Langmuir-Blodgett film preparation / Porfirinas polimetaladas com complexos periféricos de rutênio com aplicações em catálise homogênea, óptica não linear e montagem de filmes de Langmuir-Blodgett
A novel metaloporphyrin with ruthenium complexes, {H2-TPyP[RuCl(dppb)(Xbipy)] 4}(PF6)4 and {M-TPyP[RuCl(dppb)(X-bipy)]4}(PF6)4, (where M = Mn(III), Co(II) and Zn(II), X = Me- MeO- and Cl-) has been synthesized and structurally characterized by 31P{1H} magnetic resonance, UV-Vis and IR spectroscopy, cyclic voltammetry and CHN. The catalytic activity of {Mn-TP
Publicado em: 2007
-
11. Sistemas químicos integrados via complexos de rênio(I) e rutênio(II) na conversão de energia / Chemical integrated systems via rhenium and ruthenium complexes on energy conversion
The focus of this work is on two chemical integrated systems: dye-sensitized solar cells, Dye-Cells®, and photosensors based on rhenium(I) compounds. Novel ruthenium(II) compounds were synthesized, characterized and investigated as dye-sensitizers. The results of solar cells sensitized by cis-[(H3BCN)2Ru(dcbH2)2], H3BCN- = cyanoborohydride, dcbH2 = acid-4,4
Publicado em: 2007
-
12. INFLUENCE ANALYSIS OF THE SWITCHING FREQUENCY AND INPUT CURRENT RIPPLE ON THE PFC CONVERTER DESIGN AIMING TO MINIMIZE THE MAGNETIC VOLUME / ANÁLISE DA INFLUÊNCIA DA FREQÜÊNCIA DE COMUTAÇÃO E DA ONDULAÇÃO DA CORRENTE DE ENTRADA NO PROJETO DE CONVERSORES PFC PARA MINIMIZAÇÃO DO VOLUME DE MAGNÉTICOS
This work investigates the relationship among the magnetic volume, switching frequency and input current ripple of a single-phase, 1kW boost based PFC converter with universal input voltage range, complying with the international standards IEC 61000-3-2 and CISPR 22. Such topology is frequently applicable in Telecom power supplies modules, as a part of a Dis
Publicado em: 2006