Point Spread Function And Modulation Transfer Function
Mostrando 1-6 de 6 artigos, teses e dissertações.
-
1. Simulation of optical and physiological phenomena of the human vision / Simulação de fenômenos óticos e fisiológicos do sistema de visão humana
The increase in performance of the modern computers has driven scientific work in the areas of computer simulation. Many authors use in their research commercial tools that use embedding algorithms, which sources are not provided, and it makes harder and sometimes impossible, the development of novel theories or experiments. This work explores this gap left
Publicado em: 2008
-
2. Estimação da resolução espacial da câmera CCD dos satélites CBERS 1 e 2 / Spatial resolution estimation of CBERS CCD camera
The first China-Brazil Earth Resources Satellite (CBERS-1) was launched in 1999 and was substituted on 2003 by CBERS-2. CBERS- 1 and CBERS-2 have the same specifications and carry three sensors: a Wide Field Imager (WFI), a High Resolution CCD Camera (CCD) and an Infrared Multispectral Scanner (IRMSS). Due to the limitations of the sensor components (diffrac
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 21/03/2005
-
3. Caracterização de um sistema imageador infravermelho termal através de suas resoluções espacial e radiométrica / Characterization of a thermal infrared line scanner trough its spatial and radiometric resolutions
A faixa espectral do infravermelho termal para sensores aerotransportados ainda é pouco explorada no País. O Instituto de Estudos Avançados (IEAv) do Centro Técnico Aeroespacial (CTA) desenvolveu o Sistema Imageador Infravermelho Termal (SISIMI), um sensor-protótipo termal aerotransportado que opera na faixa de 8 a 12,5 µm e com imageamento por varredu
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 09/10/2002
-
4. Caracterização de um sistema imageador infravermelho termal através de suas resoluções espacial e radiométrica / Characterization of a thermal infrared line scanner trough its spatial and radiometric resolutions
The thermal infrared spectral bands in airborne sensors are still little explored in Brazil. The Institute of Advanced Studies (IEAv) at the Aerospace Technical Center (CTA) developed the Thermal Infrared Imaging System (SISIMI), an aerial surveillance prototype sensor operating in the 8 to 12.5 um band with a rotating imaging scanner of 720 lines/s. The obj
Publicado em: 2002
-
5. Caracterização de um sistema imageador infravermelho termal através de suas resoluções espacial e radiométrica / Characterization of a thermal infrared line scanner trough its spatial and radiometric resolutions
A faixa espectral do infravermelho termal para sensores aerotransportados ainda é pouco explorada no País. O Instituto de Estudos Avançados (IEAv) do Centro Técnico Aeroespacial (CTA) desenvolveu o Sistema Imageador Infravermelho Termal (SISIMI), um sensor-protótipo termal aerotransportado que opera na faixa de 8 a 12,5 µm e com imageamento por varredu
Publicado em: 2002
-
6. Avaliação ponto a ponto de sistemas de imagem radiológica utilizando funções de espalhamento de ponto simuladas. / Evaluating the focal sopt MTF in all radiological field location by computer simulation.
In this work a method of evaluation for the radiological imaging systems performance by simulated transfer functions for any X-ray field region is proposed. The simulation procedures provide information of the changes of the focal spot sizes and, therefore, of the Point Spread Function (PSF) along the field. The evaluation yields the bi-dimensional optical T
Publicado em: 1994