1. Simulation of Current Pulses and Sound Waves Resulting from Partial Discharges in a Needle-Plane Geometry in Air
Abstract Partial discharges can occur in different types of electric equipment and cause progressive insulation deterioration, so there is interest in monitoring partial discharges for assessing the state of the isolation of an electric system and to predict failures. Techniques to detect partial discharges, such as detecting ultrasonic emission, have been p
Journal of Microwaves, Optoelectronics and Electromagnetic Applications. Publicado em: 2022
-
2. Is there a role for sacral neuromodulation in patients with neurogenic lower urinary tract dysfunction?
ABSTRACT Purpose To review current literature regarding sacral neuromodulation (SNM) for neurogenic lower urinary tract dysfunction (NLUTD) focused on indications, barriers and latest technological developments. Material and Methods A PubMed database search was performed in April 2020, focusing on SNM and various neuro-urological conditions. Results SN
Int. braz j urol.. Publicado em: 2020-12
-
3. Chemometric Optimization of the Methodology for Determination of Molybdenum in Soils and Plants by Square Wave Adsorptive Stripping Voltammetry
The method is based on the adsorptive accumulation of complex molybdenum(VI) with 8-hydroxyquinoline, using voltammetric square wave cathodic stripping voltammetry. The composition and concentration of the supporting electrolyte, frequency (Hz), amplitude (mV) and deposition time (s), were optimized by factorial design in relation to current reduction of mol
J. Braz. Chem. Soc.. Publicado em: 2020-04
-
4. Effect of Electric Pulse Treatment on the Corrosion Resistance of HAl52-2 Aluminum Brass
In this work, the effects of electric pulse treatment (EPT) on the corrosion resistance of HAl52-2 aluminum brass has been investigated using electrochemical workstation, scanning electron microscope and X-ray diffraction. The results have shown that after EPT, the corrosion potential increased and the corrosion current density decreased. At the same time, t
Mat. Res.. Publicado em: 19/08/2019
-
5. Caracterización de compositos biocerámicos en esponjas de titanio mediante interpenetración por corriente pulsada asistida
ABSTRACT Recently, it has been directing some special attention to the development of new manufacturing processes, with engineering applications in human tissues [1]. 3D printing applied to tissue engineering requires pulse computational techniques such as stereolithographic modeling, and special manufacturing processes, to name a few; Laser Sintering or Ext
Matéria (Rio J.). Publicado em: 19/07/2018
-
6. Pulse Eletrodeposition of Ni/nano-Al2O3 Composite Coatings on Cast Iron Cylinder Liner
Ni/nano-Al2O3 composite coating by pulse electrodeposition method has been used for coating on cast iron liner material. The hardness has been increased from 308 HV to 1050 HV through conventional Watts bath and by applying Taguchi's optimization technique with optimum parameters of pulse frequency 120 Hz, duty cycle 40% and peak current density 0.7A/cm2. Th
Mat. Res.. Publicado em: 26/03/2018
-
7. A Comparative Study on Ag-Doped and Surfactant Assisted MnO2 Prepared by Direct and Pulse Current Electrodeposition on Surgical Grade Stainless Steel as High-Performance Supercapacitor
Direct and pulse current electrodeposition techniques were applied for preparation of novel electro-active manganese oxides. The influences of Ag doping and addition of cetyltrimethylammonium bromide (CTAB) on electrochemical properties were discussed. The morphology and structure of the electrodes are studied by different techniques including field emission
J. Braz. Chem. Soc.. Publicado em: 2017-01
-
8. Surface Modification of Aluminized Cu-10Fe Alloy by High Current Pulsed Electron Beam
A Cu-10Fe alloy with magnetron sputtered Al films was irradiated by high current pulsed electron beam (HCPEB) with various pulse numbers, next changes of its microstructure and corrosion property were investigated. Compared with the initial sample, microhardness and corrosion resistance of the aluminized Cu-10Fe alloys after the HCPEB treatment are remarkabl
Mat. Res.. Publicado em: 24/11/2016
-
9. Comparative Study of Magnetic Properties and Microstructure for As-cast and Square-wave Pulse Current Joule Annealed Wires
We here report on a comparative study of the microstructure and magnetic properties of as-cast and SPCJA-ed Co-based wires for potential sensor applications. Experimental results indicate that both as-cast and SPCJA-ed wires exhibit typical amorphous feature. There also exists the enhanced local ordering degree of atomic arrangement and obvious transformatio
Mat. Res.. Publicado em: 23/10/2015
-
10. Preparation of a Nitrite Electrochemical Sensor Based on Polyaniline/ Graphene‑Ferrocenecarboxylic Acid Composite Film Modified Glass Carbon Electrode and its Analytical Application
A sensitive and stable electrochemical sensor based on polyaniline/graphene-ferrocenecarboxylic acid (PANI/GR-FCA) composite film modified glass carbon electrode for determination of nitrite was presented and its morphology and structure were characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), Fourier transform infrar
J. Braz. Chem. Soc.. Publicado em: 2015-10
-
11. Method to Determine the Electrical Energy for Ignition of Electro-Explosive Devices
ABSTRACT: During field trials, it was observed that the delay of ignition of electro-explosive devices (EED) depends on ratings of power supplies or dynamo and also on the firing cable lengths. The change in ignition delay of EEDs due to altered supplied current will detoriate the repeatability of sequence of actions in time-critical armament applications. I
J. Aerosp. Technol. Manag.. Publicado em: 2015-09
-
12. Determination of anti-cancer drug emodin using a silica-gel-modified carbon paste electrode
In this paper, a silica-gel-modified carbon paste electrode (Si-gel/CPE) was used to determine the anti-cancer drug emodin by anodic stripping differential pulse voltammetry (ASDPV). The effects of the silica-gel content, the pH of the supporting electrolyte, and the scan rate on the oxidation current of emodin were investigated. The oxidation currents of em
Quím. Nova. Publicado em: 2014