Tld Dosimeter
Mostrando 1-5 de 5 artigos, teses e dissertações.
-
1. Determination of dosimetric quantities of interest in Mammography using thermoluminescent detectors. / Determinação de grandezas dosimétricas de interesse em mamografia usando detectores termoluminescentes
National and international health organizations such as the Brazilian Ministry of Health, through its Secretary of Health Surveillance establishes in the publication Nº 453/98 that in all mammographic equipments must be evaluated the entrance-skin dose through the readings of an ionization chamber-electrometer system corrected by the backscatter factor, amo
Publicado em: 2010
-
2. Caracterização do campo de nêutrons na instalação para estudo em BNCT no Reator IEA-R1 / NEUTRON FIELD CHARACTERIZATION IN THE INSTALLATION FOR BNCT STUDY IN THE IEA R1 REACTOR.
This work aims to characterize the mixed neutron and gamma field, in the sample irradiation position, in a research installation for Boron Neutron Capture Therapy (BNCT), in the IPEN IEA-R1 reactor. The BNCT technique has been studied as a safe and selective option in the treatment of resistant cancerigenous tumors or considered non-curable by the convention
Publicado em: 2008
-
3. SEMI-EMPIRICAL SIMULATION OF THERMOLUMINESCENT RESPONSE UNDER DIFFERENT FILTER GEOMETRIES / "Simulação semi-empírica da resposta termoluminescente sob diferentes geometrias de filtro"
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproductibility, small fading and simple glow curve with peaks above 150oC. Calcium S
Publicado em: 2006
-
4. Individual monitoring for external exposures: experimentation and simulation with Monte Carlo Method / Monitoração individual externa: experimentos e simulações com o método de Monte Carlo
In this work, we have evaluated the possibility of applying the Monte Carlo simulation technique in photon dosimetry of external individual monitoring. The GEANT4 toolkit was employed to simulate experiments with radiation monitors containing TLD-100 and CaF2:NaCl thermoluminescent detectors. As a first step, X ray spectra were generated impinging electrons
Publicado em: 2005
-
5. Propriedades dosimétricas dos ossos / Dosimetric properties of bones
The purpose of this work is to evaluate the possibilities of the use of bone as a dosimeter. This method is based upon measurement of EPR absorption lines intensities f centers created by ionizing radiation. Applying this method it has been possible to measures doses about 10 rad for X rays and 50 rad for ϒ rays of Co60.The methodology for sample prepara
Publicado em: 1982